Home ProductsBrewery and Winery Glycol Chiller

-5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors

-5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors

    • -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
    • -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
    • -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
    • -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
    • -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
  • -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors

    Product Details:

    Place of Origin: China
    Brand Name: MGREENBELT
    Certification: CE
    Model Number: MG-40CL(D)

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: USD 5000 - 12580
    Packaging Details: Plywood case for export
    Delivery Time: 10 -25 days
    Payment Terms: T/T,L/C,Western Union
    Supply Ability: 500sets per month
    Contact Now
    Detailed Product Description
    Cooling Capacity: 71kw@ -5C Compressor Type: Scroll Type
    Compressor Quanity: 2 Or 4 Compressor Brand: Copeland Or Panasonic
    Air Volume: 40000m3/hr Refrigerant: R410a , R407c, R404a
    Evaporator Type: Shell And Tube Type Condenser: Copper Tube Covered Aluminum Fins
    Inlet And Outlet Pipe Size: DN65 Outlet Water Temperature Control: -10C ~ +30C
    Warranty: 12 Months After Shipment

    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
     

    Design of 40hp glycol chiller 


    (1). Design waterproof ,suitable using outside and in house.
    (2)  Design working condition ambient temperature from -20C degree to +50C degree.
    (3). Working condition: good air circulation place to discharge the heat.
    (4). Remote and local control available.
    (5). Power off - Auto strart up turn on function supported.
    (6). Inlet and outlet pipe stainless steel;
    (7). This 40hp chiller adopt 2 or 4unit compressors, each circuit working and control automcatically depends on the brewing system load.
    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
     

    Features of 40hp glycol chiller

    1) Adopted world famous brand Copeland compressors and high efficiency condenser and evaporator, ensure high cooling efficiency, low energy consumption, low noise and long service life.
    2) Chilled water temperature range control -10C to +30C.
    3) R22 charged, CFC free type R407C, R410A, R404A for option, high cooling efficiency.
    4) Over sized evaporator and condenser ensure the chiller unit running under 45C high ambient temperature.
    5) Microcomputer control system offering accurate temperature stability within ±1ºC.
    6) Low noise and big volume air blower.
    7) Standard equipped Iron pump, stainless steel or high lift pump for option.
    8) The innovative evaporator-in-tank configuration ensures a steady water temperature offered, as the evaporator also cools the tank itself, reduces ambient heat gain, and increases the efficiency.
    9) Industrial air cooled water chiller adopted aluminum fin/copper tube type condenser, easy for cleaning and installation.
    10) Muti- protection devices ensure the chiller unit running safely: -Compressor inner protection,Over current protection,High/low pressure protection,Over temperature protection ,Flow switch,Phase sequence/phase missing protection,Low coolant level protection,Anti freezing protection ,Exhaust overheat protection.
     
    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors-5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors-5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
     

    Technical specification for different models

    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
     

    Finished pictures of 40hp glycol chiller

     
    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors-5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
     

    Applications of glycol chiller

     
    Mgreenbelt Air Cooled Water Chiller are widely used in the brewery and winery, Chemical Industry,Food and beverage, Ultrasonic wave cooling, and other industrial production. It can precisely control the exactly temperature , which requested by the modernized machinery production, and greatly improved the production efficiency and product quality. MGREENBELT Industrial chiller is a good partner for the modernized industry , which feather as easy to operate with reasonable design, high quality and complete range of specifications.
     

    Working site of water chiller:

    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors

    Company information

    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors-5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
     

    More Different industrial chillers in production

    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors

    Service

    A. Order service
    Inquiry-Quotation-Agreement-Order Confirm-Proforma Invoice-Deposit Payment-Production-Testing --Balance Payment- Packing &Delivery--Documents Dispature- Assist of custom-cleaning --Instruction of Installation&Operation-Feedback
    B. Technical service
    1, We calculate the capacity and recommend the best models.
    2, We design and develop the new products according to your requirement besides our standard products.
    3, We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
    4, We supply the spare parts and technical support in & after the warranty time.
    5, We supply the training course to your workers at our factory if you need.
    C. After sale service
    1. One-Year guarantee for whole unit and all parts free
    2. Life time maintenance
    3. Machines have to be strictly adjusted before delivery and deliver with firm & reliable packing and transportation.
    4. Supply the professional refrigeration technical support and electronic technical support for your installation, debugging, operation and maintenance.
    5. Supply free training course to your workers at our factory if you need.
    6. Supply the spare parts and technical support in & after the warranty time.
    7. Spare parts and technical support at most economic prices after the warranty.
    8. 24 hours on line service each day by telephone.
    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors

    FAQ


    Q1: How to choose the right chiller?
    A1:
    1).Power supply voltage : PH/ V/ HZ?
    2).Refrigerant type R22(Freon ) or CFC free one R407C?
    3).What is the cooling capacity requests , KW?
    4). What is the outlet water temperature and return water temperature to chiller?
    5). Do you have the requests for the water flow rate , water pressure and water quality?
    6). For what kind of equipment or cooling system( Close loop or open loop ) in your side?
    7). What is the maximum ambient working temperature in your factory?

    Q2: What power supply chiller you can produce?
    A2: Our standard power supply is 3phase-380V-50Hz, Customzied different for optaions, like 3phase- 415V,440V,460V,480V,- 50Hz or 60Hz

    Q3:What is your Payment terms?
    A3:Standard is 50% in advance to production, the balance before shippment, this mainly depends on the order.

    Q4:What refrigerant you can supply?
    A4: We have R22, Eeo friendly R407c, R410a, R134a,R404a depends on your choice.

    Q5:This model and type chiller is not what I need, what should I do?
    A5:Please tell us the Q1, or your further requirements, then the solution will be sent to your email with prompt.

    -5C/-10C Low Temperature 40HP Glycol Chiller for Brewery with R404A Copeland Compressors
    Welcome to china and visit our company and factory. You can get me any time by following :
    Libra Zhang
    M: 008618769762328
    Whatsapp/Viber : +8618769762328
    E: chillercompressor at gmail dot com
    Skype: libra5813
    QQ: 2053526507

     

    Contact Details
    Shandong Mgreenbelt Machinery Co.,Ltd

    Contact Person: Ms. Libra Zhang

    Tel: 86-187-69762328

    Fax: 86-531-88081230

    Send your inquiry directly to us (0 / 3000)